Introduction
Turner Hydraulic Site Services Ltd received oil sample(s) from Celsa Manufacturing (UK) for us to carry out a particle count and a patch test with photographic evidence.
Test Programme
The test equipment used for the particle count measurement was a HYDAC FCU 2110.
The patch tests are carried out using the ISO 4406 standard test amount of 100ml drawn through a 1.2 micron membrane and the resulting membrane mounted in a petri slide and viewed under a video linked high resolution microscope. The high resolution mavigraph photographs are taken from the patch test membranes and are at x10 and x100 magnification.
Analysis and Instrument Parameters
Particle distribution measurement according to ISO/DIS 11500.
Instrument: Particle counter with laserdiode sensor calibrated to ISO 4402 with ISOMTD.
Results
Turner Hydraulic Site Services Ltd received oil sample(s) from Celsa Manufacturing (UK) for us to carry out a particle count and a patch test with photographic evidence.
Test Programme
The test equipment used for the particle count measurement was a HYDAC FCU 2110.
The patch tests are carried out using the ISO 4406 standard test amount of 100ml drawn through a 1.2 micron membrane and the resulting membrane mounted in a petri slide and viewed under a video linked high resolution microscope. The high resolution mavigraph photographs are taken from the patch test membranes and are at x10 and x100 magnification.
Analysis and Instrument Parameters
Particle distribution measurement according to ISO/DIS 11500.
Instrument: Particle counter with laserdiode sensor calibrated to ISO 4402 with ISOMTD.
Results